Before you start
You will need a flashlight and to know where three things are: the pressure tank (the blue or grey tank, usually in the basement or a utility room), the pressure switch (the small grey box with a cover on the pipe beside the tank), and the breaker for the pump. If you cannot find the breaker, it is often labelled “well” or “pump” and is a double breaker. Everything below is looking, not fixing; if a step calls for opening an electrical cover, stop and call us instead.
1. Is it every tap, or one?
Run the kitchen cold, a bathroom tap and an outside hose bib. One dead tap with the rest working is a frozen or blocked line to that fixture, not a well problem. Every tap dead, or every tap sputtering, is the well system.
2. Look at the pressure gauge
The gauge on the tank tee normally reads somewhere between 30 and 60 psi. If it reads zero and nothing is happening, the pump is not running: go to the breaker. If it reads zero and you can hear the pump humming or running, the pump is running but not moving water: it could be pulling air from a low well, a broken drop pipe, or a failed check valve. If the gauge reads 40 or more and you still have no water, the problem is between the tank and the taps, often a frozen or closed line or a clogged filter.
3. The breaker
Look at the pump breaker in the panel. A tripped breaker sits between on and off. Switch it fully off, then on, once. If the pump starts and pressure climbs, you are back in business for now, but a breaker that tripped once will trip again: a pump drawing high amps, a nicked wire down the well, or water in the control box. If it trips again immediately, leave it off and call us. Do not keep resetting it; each reset is a hit to the motor.
4. The pressure switch
With the breaker on, listen at the switch. A loud click when pressure drops and the pump starting is normal. Silence, or a click with no pump, points to the switch, the control box or the pump. Burnt contacts in the switch are the single most common no-water cause we find, and the cheapest. If the switch has a lever on the side, it is a low-pressure cut-off switch: lift and hold the lever for 30 seconds to let the pressure build, then release. If pressure climbs and holds, you are running again; if it drops right back, something upstream is wrong.
5. Is anything frozen?
In winter, check the line where it enters the house, the pump house if you have one, and any pipe along an outside wall or in a crawlspace. A frozen section feels colder than the pipe either side of it and may be frosted. Warm it with a hair dryer or a space heater from a distance; never a torch. A well pitless adapter below the frost line almost never freezes, but a shallow line to an outbuilding or a cottage does.
6. The filter and the softener
A sediment filter that has not been changed in a year can block flow completely, especially after a storm stirs up the well. A softener stuck mid-regeneration can do the same. Put the softener on bypass and, if the filter housing has one, open the bypass; if water comes back, you have found it.
7. Tap the tank
Tap the pressure tank from top to bottom. It should sound hollow on top and dull at the bottom. Dull all the way up means the tank is waterlogged; it will not stop the water on its own, but it makes the pump short-cycle until it fails, and a pump that failed after months of short-cycling is a common end to this story.
8. Did the power flicker?
Rural outages and surges knock out control boxes and trip pump breakers. If the neighbours lost power too, check the breaker and the control box first. A control box that is buzzing, hot or smells burnt has likely lost its capacitor, which is a quick swap.
9. Is the well low?
Water that comes back after the pump rests for an hour and quits again under heavy use is a well that is being drawn down, usually in late summer. Shut the pump off between uses so it does not run dry and burn out, and read our guide on what to do when a well runs dry.
10. Tell us what you found
When you call, say what the gauge reads, whether the breaker was tripped, whether the switch clicks, and what you shut off. It changes what the plumber loads on the truck and often turns a two-visit job into one. No-water calls on a well are treated as emergencies across our whole service area, day or night; weekdays the $45 service call covers the trip and the diagnosis, and after-hours is quoted before we leave. You approve the repair price before any work starts.